<LOGO>
FM Transmitter Measurement Report
Created: 2023-02-23 13-19-03
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 5/5, 42 dBuV INTER
Pilot RDS Phase Difference
7.3 kHz 2.6 kHz 53 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 63 kHz 15937 0,1067
Modulation Power
Limit Measuring Tolerance
9,0 dBr 0,0 dBr
MIN AVE MAX % above 9,0 dBr
1,4 dBr 2,28 dBr 3,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 --:--
RT
"LE 13/14 - FRANCE INTER 1ERE RADIO DE FRANCE "
AF EON
87.8, 88.1, 92.6, 93.0, 93.2, 93.8, 94.6, 94.9, 95.0, 95.1, 96.3, 96.5, 96.8, 99.2, 99.4, 99.5, 99.6, 99.9, 100.2, 100.7, 101.9 MHz F203, F208, F222, F209
FM Scope Station: 100.20 MHz, signal: 5/5 (42 dBuV) Max at: 63 kHz MIN: 11 kHz % above 75 kHz: 0,1067 Acquired: 2023/02/23 13:17:59 Total samples: 15937 Equivalent time: 0:13:16 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 3,0 dBr MIN: 1,4 dBr AVE: 2,28 dBr % above 9,0 dBr: 0,0 Last value: 2,0 dBr (2023/02/23 13:17:58) Station: 100.20 MHz, signal: 5/5 (42 dBuV) 13:06 13:08 13:10 13:12 13:14 13:16 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality